Heatmiser for Underfloor Heating in London
Heatmiser is our preferred smart control system for wet underfloor heating across London's prime properties. The NeoStat thermostat's floor sensor input, per-zone scheduling and OpenTherm modulation make it the gold standard for UFH control — particularly where expensive floor finishes require active temperature protection.
Heatmiser UFH Quote
Tell us about your UFH system and floor finishes.
Built for underfloor heating — not just adapted for it.
Most smart thermostats were designed for conventional on/off radiator control and adapted for UFH. Heatmiser was built from the ground up for the UK market, with UFH as a primary use case — and the technical difference shows.
Floor Sensor Protection
The NeoStat's dedicated floor sensor input protects engineered timber, stone and tile from overheating — critical for expensive floor finishes.
Multi-zone on one app
Control every UFH zone and any radiator zones in the same property from a single NeoHub and one app — including mixed systems.
OpenTherm modulation
For compatible boilers, Heatmiser uses OpenTherm to modulate rather than on/off — far more efficient for low-temperature UFH circuits.
Independent scheduling
Every zone has its own independent schedule, set-point and boost — not a single programme for the whole house.
Why floor sensor protection matters in London's high-spec interiors.
Across Mayfair, Marylebone, Hampstead and Knightsbridge, we regularly work in homes with engineered oak, Versailles parquet, heated marble and porcelain tiles. Every one of these floor finishes has a maximum recommended operating temperature — typically 27°C for timber and 29°C for tile and stone.
Without a floor sensor, the UFH system cannot measure the floor surface temperature — it can only measure the air temperature. On a cold morning with the system calling hard, the floor temperature can significantly exceed these limits before the air temperature reaches set-point, causing damage to the floor finish that is expensive and sometimes impossible to remediate.
The Heatmiser NeoStat's floor sensor input solves this directly. We install a temperature probe beneath the floor finish, and the thermostat monitors the floor surface continuously — overriding the heating call if the floor temperature approaches the limit, regardless of what the air temperature is doing.
How we integrate Heatmiser with your UFH manifold.
- 1
Survey & zone layout
We assess the existing manifold, confirm actuator compatibility, and design the thermostat layout.
- 2
Actuator installation
Zone valve actuators are fitted to each manifold port, wired back to the NeoStat thermostats.
- 3
Floor sensor installation
Where required (timber floors particularly), floor temperature probes are installed via a conduit in the screed.
- 4
NeoHub commissioning
All zones are commissioned individually, tested for correct valve operation, and configured in the app.
- 5
Boiler integration
The NeoHub is connected to the boiler — via OpenTherm if compatible — and the heat demand logic is tested across all zones.
Recent UFH + Heatmiser project.

Full UFH installation — 8 zones, Hampstead extension
120m² rear extension with architect-specified wet UFH across 8 independent zones. 18mm low-profile overlay system. Existing Heatmiser NeoHub expanded to accommodate the new zones — total property now 12 independently controlled zones on one app.
Heatmiser for UFH — common questions.
UFH Controls Quote
Expert Heatmiser installation for your underfloor heating.
020 7458 4949Get a Quote