Underfloor Heating Repairs London — Cold Spots, Manifold Faults & Leak Detection

Faulty underfloor heating? We find and fix cold spots, manifold faults, leaks and balancing issues — without lifting your floors. Thermal imaging diagnosis by Heatmiser-certified engineers.

Gas Safe Registered
Available 7 Days
4.7★ Rated
13+ Years Experience

Book a Repair Visit

Available 7 days. Thermal imaging diagnosis included.

Attach Photos & Videos (optional)

Help us understand the job — add up to 5 photos or short videos (max 50MB)

Or call us directly: 020 7458 4949

Transparent Pricing

Clear rates — no call-out fee, no surprises

We charge a straightforward hourly rate with no separate charge for attending. The clock starts when the engineer arrives — not before. Any parts needed are quoted transparently before work begins, so you'll always know the cost upfront.

£150/hr + VAT

No call-out fee · Minimum 1 hour

Standard rate (Mon–Fri, 8am–6pm)£150/hr + VAT
Out-of-hours (evenings & weekends)£195/hr + VAT
Bank holidays (incl. Christmas)£275/hr + VAT
Replacement partsQuoted before work begins
No charge for attending — you only pay for time on site
Fixed quote before any parts are fitted
RARE members save 10% on standard rates
London's UFH Repair Specialists

Diagnosis from the physics of the system

Most underfloor heating faults we see were caused at installation — pipes spaced too far apart, too little floor insulation, systems never properly balanced, or filled with London's untreated hard water.

RARE's engineers diagnose every fault from the physics of the system. We measure flow rates before claiming a manifold is balanced. We use thermal imaging to find cold spots without lifting floors. We test water chemistry to identify corrosion and scale. This is why our diagnostic visits find the root cause — not just the nearest replaceable component.

Cold spot diagnosis without lifting floors
Manifold repairs & full servicing
Balancing circuits so every room heats evenly
Sludge & debris flushing
Heatmiser NeoHub fault diagnosis & repair
Pump & blending valve replacement
Concealed leak detection via thermal imaging
Actuator replacement & manifold component repair

Book a UFH Diagnostic Visit

We diagnose the fault, explain the cause and provide a fixed-price repair quote — no obligation.

020 7458 4949Book a Repair Visit

Area Coverage

Mayfair Belgravia Knightsbridge Chelsea Kensington Holland Park Notting Hill Marylebone St John's Wood Hampstead Primrose Hill Westminster
Technical Reference

Manifold diagnostic guide — how we find the fault

Every UFH fault has a systematic diagnostic path. Our engineers work through each possibility methodically — never replacing parts by guesswork. This is the same process we follow on every diagnostic visit.

All zones cold — no heat anywhere

Urgent

Likely Cause

Circulation pump failure or blending valve fully closed

Diagnostic Test

Check pump operation at manifold. Measure supply/return delta-T — should be 5–10°C. Zero delta-T confirms no circulation.

Resolution

Pump replacement (2–3hr job). Blending valve service or replacement.

One zone cold, all others warm

Standard

Likely Cause

Failed actuator (stuck closed), blocked circuit, or seized flow meter

Diagnostic Test

Remove actuator manually — open port by hand. If zone warms up, actuator is faulty. If still cold, check flow meter reads correct l/min.

Resolution

Actuator replacement (30-min job). If blocked: circuit flush with portable flushing pump.

Uneven heat across a single room

Standard

Likely Cause

Magnetite settled in lower pipe loops, air lock, or manifold flow imbalance

Diagnostic Test

Thermal camera scan of floor confirms cold pipe loops. Flow meter readings at manifold show imbalanced circuits.

Resolution

Power flush of affected circuit. Flow meter rebalance. Magnetic filter installation at manifold return.

System runs continuously, floor overheating

Urgent

Likely Cause

Blending valve stuck open or set too high. Failed room thermostat or actuator stuck open.

Diagnostic Test

Measure flow temperature at manifold supply — exceeds setpoint (typically >50°C indicates valve fault). Check actuator closes when thermostat calls off.

Resolution

Blending valve calibration or replacement. Actuator/thermostat replacement.

Manifold leaking — drips from fittings

Urgent

Likely Cause

Compression fitting corrosion (common with aggressive London water), cracked manifold body, failed O-ring on actuator port.

Diagnostic Test

Visual inspection with system pressurised to 1.5 bar. Identify leak point. Check pH and inhibitor concentration in system water.

Resolution

Fitting replacement. Manifold body replacement if cracked. Water quality correction to prevent recurrence.

Thermostat calls for heat but boiler does not fire

Standard

Likely Cause

Wiring fault between room stat/actuator and boiler demand signal. NeoHub communication fault.

Diagnostic Test

Test voltage at actuator (230V when calling). Check demand wire continuity at boiler terminals. Test NeoHub connectivity.

Resolution

Rewire demand circuit. NeoHub factory reset and re-pair. Replace faulty actuator with open-therm compatible type.

Manifold losing pressure — concealed leak

Urgent

Likely Cause

Micro-leak in a buried UFH pipe at a joint, or manifold fitting weep under pressure

Diagnostic Test

Pressure-test each circuit individually at the manifold — isolate one loop, pressurise to 1.5 bar and monitor. A leaking circuit loses pressure while others hold. Thermal imaging confirms the leak location beneath the floor.

Resolution

If at a manifold joint: fitting replacement. If in screed: localised floor lifting at the identified leak point, pipe repair, re-pressurisation and re-screed.

Can't find your symptom here?

Call our engineers on 020 7458 4949 — we'll diagnose your UFH fault over the phone before arranging a visit.

What our clients say

4.7★ across 120+ verified reviews

"Had persistent cold spots for two years. Two other companies replaced actuators without success. RARE did a thermal camera scan, found a partial magnetite blockage in the north circuit, flushed it and rebalanced. Fixed in one visit."

Fiona M.

Holland Park, W11

"Our UFH manifold was leaking and two engineers couldn't find the source. RARE pressure-tested each circuit individually, found the weeping fitting and replaced it without lifting any floor. Professional and methodical."

Alex C.

Belgravia, SW1

"Underfloor heating stopped working entirely on a Saturday. RARE came out the same day — turned out to be a failed circulation pump at the manifold. Replaced and commissioned within two hours. Excellent service."

James W.

Hampstead, NW3

FAQ

UFH Repair Questions Answered

Our engineers answer these questions every day. Still not sure? Call us and speak to an engineer directly.

Speak to an engineer

Property Care Membership

Prefer proactive care? RARE members receive planned servicing, detailed property records and priority access when problems arise. Explore Property Care Membership for professionally managed plumbing and heating maintenance.

Authoritative Sources & References

  • Wikipedia
    Central heating — Wikipedia

    Wikipedia — Encyclopaedic overview of central heating systems, heat generation, circulation methods and the history of whole-building heating.

  • Wikipedia
    Boiler — Wikipedia

    Wikipedia — Reference on the design and operation of closed-vessel boilers used for central heating and hot water generation.

Reviewed by RARE Plumbing London Engineering Team

Gas Safe Registered Heating Engineers · Reviewed 21 September 2026