Underfloor Heating Repairs London — Cold Spots, Manifold Faults & Leak Detection
Faulty underfloor heating? We find and fix cold spots, manifold faults, leaks and balancing issues — without lifting your floors. Thermal imaging diagnosis by Heatmiser-certified engineers.
Book a Repair Visit
Available 7 days. Thermal imaging diagnosis included.
Clear rates — no call-out fee, no surprises
We charge a straightforward hourly rate with no separate charge for attending. The clock starts when the engineer arrives — not before. Any parts needed are quoted transparently before work begins, so you'll always know the cost upfront.
No call-out fee · Minimum 1 hour
Diagnosis from the physics of the system
Most underfloor heating faults we see were caused at installation — pipes spaced too far apart, too little floor insulation, systems never properly balanced, or filled with London's untreated hard water.
RARE's engineers diagnose every fault from the physics of the system. We measure flow rates before claiming a manifold is balanced. We use thermal imaging to find cold spots without lifting floors. We test water chemistry to identify corrosion and scale. This is why our diagnostic visits find the root cause — not just the nearest replaceable component.
Book a UFH Diagnostic Visit
We diagnose the fault, explain the cause and provide a fixed-price repair quote — no obligation.
020 7458 4949Book a Repair VisitArea Coverage
Manifold diagnostic guide — how we find the fault
Every UFH fault has a systematic diagnostic path. Our engineers work through each possibility methodically — never replacing parts by guesswork. This is the same process we follow on every diagnostic visit.
All zones cold — no heat anywhere
UrgentLikely Cause
Circulation pump failure or blending valve fully closed
Diagnostic Test
Check pump operation at manifold. Measure supply/return delta-T — should be 5–10°C. Zero delta-T confirms no circulation.
Resolution
Pump replacement (2–3hr job). Blending valve service or replacement.
One zone cold, all others warm
StandardLikely Cause
Failed actuator (stuck closed), blocked circuit, or seized flow meter
Diagnostic Test
Remove actuator manually — open port by hand. If zone warms up, actuator is faulty. If still cold, check flow meter reads correct l/min.
Resolution
Actuator replacement (30-min job). If blocked: circuit flush with portable flushing pump.
Uneven heat across a single room
StandardLikely Cause
Magnetite settled in lower pipe loops, air lock, or manifold flow imbalance
Diagnostic Test
Thermal camera scan of floor confirms cold pipe loops. Flow meter readings at manifold show imbalanced circuits.
Resolution
Power flush of affected circuit. Flow meter rebalance. Magnetic filter installation at manifold return.
System runs continuously, floor overheating
UrgentLikely Cause
Blending valve stuck open or set too high. Failed room thermostat or actuator stuck open.
Diagnostic Test
Measure flow temperature at manifold supply — exceeds setpoint (typically >50°C indicates valve fault). Check actuator closes when thermostat calls off.
Resolution
Blending valve calibration or replacement. Actuator/thermostat replacement.
Manifold leaking — drips from fittings
UrgentLikely Cause
Compression fitting corrosion (common with aggressive London water), cracked manifold body, failed O-ring on actuator port.
Diagnostic Test
Visual inspection with system pressurised to 1.5 bar. Identify leak point. Check pH and inhibitor concentration in system water.
Resolution
Fitting replacement. Manifold body replacement if cracked. Water quality correction to prevent recurrence.
Thermostat calls for heat but boiler does not fire
StandardLikely Cause
Wiring fault between room stat/actuator and boiler demand signal. NeoHub communication fault.
Diagnostic Test
Test voltage at actuator (230V when calling). Check demand wire continuity at boiler terminals. Test NeoHub connectivity.
Resolution
Rewire demand circuit. NeoHub factory reset and re-pair. Replace faulty actuator with open-therm compatible type.
Manifold losing pressure — concealed leak
UrgentLikely Cause
Micro-leak in a buried UFH pipe at a joint, or manifold fitting weep under pressure
Diagnostic Test
Pressure-test each circuit individually at the manifold — isolate one loop, pressurise to 1.5 bar and monitor. A leaking circuit loses pressure while others hold. Thermal imaging confirms the leak location beneath the floor.
Resolution
If at a manifold joint: fitting replacement. If in screed: localised floor lifting at the identified leak point, pipe repair, re-pressurisation and re-screed.
Can't find your symptom here?
Call our engineers on 020 7458 4949 — we'll diagnose your UFH fault over the phone before arranging a visit.
What our clients say
4.7★ across 120+ verified reviews
"Had persistent cold spots for two years. Two other companies replaced actuators without success. RARE did a thermal camera scan, found a partial magnetite blockage in the north circuit, flushed it and rebalanced. Fixed in one visit."
Fiona M.
Holland Park, W11
"Our UFH manifold was leaking and two engineers couldn't find the source. RARE pressure-tested each circuit individually, found the weeping fitting and replaced it without lifting any floor. Professional and methodical."
Alex C.
Belgravia, SW1
"Underfloor heating stopped working entirely on a Saturday. RARE came out the same day — turned out to be a failed circulation pump at the manifold. Replaced and commissioned within two hours. Excellent service."
James W.
Hampstead, NW3
You May Also Need
Underfloor Heating Installation
New wet UFH systems — heat loss calculations, screed and low-profile overlay installs.
Heatmiser Smart Controls
Heatmiser NeoHub fault diagnosis, repair and replacement.
Power Flushing
Remove magnetite from UFH circuits and restore even heat distribution.
PPM Membership
Include your UFH manifold in an annual care plan from £750/year.
UFH Repair Questions Answered
Our engineers answer these questions every day. Still not sure? Call us and speak to an engineer directly.
Speak to an engineerProperty Care Membership
Prefer proactive care? RARE members receive planned servicing, detailed property records and priority access when problems arise. Explore Property Care Membership for professionally managed plumbing and heating maintenance.
Authoritative Sources & References
- WikipediaCentral heating — Wikipedia
Wikipedia — Encyclopaedic overview of central heating systems, heat generation, circulation methods and the history of whole-building heating.
- WikipediaBoiler — Wikipedia
Wikipedia — Reference on the design and operation of closed-vessel boilers used for central heating and hot water generation.
Related reading from our Knowledge Hub